Issue link: https://resources.randsim.com/i/1504493
31 ©2023 ANSYS, Inc. Weld with Aggressive Relaxation • When Weld is Modeled As "Normal" or "Angled" or "1D" or "Normal and Angled", and the Relaxation property is set to Aggressive, sometimes Weld Face(s) fails to generate. • In such scenarios, Mechanical internally creates Mesh Independent welds through bonded MPC contact. • This applies for both options: - Worksheet - Non-worksheet (Geometry Scoping & Body Scoping)