Issue link: https://resources.randsim.com/i/1492512
157 Projected Contact for Gaskets • Send the KEYOPT(4) = 3 when ‐ If Detection Method is set to Program Controlled AND ‐ The contact is scoped to a gasket • Advantages: ‐ This setting enforces a contact constraint on an overlapping region of the contact and target surfaces rather than on individual contact nodes ‐ Prevents displacement overshoot for gasket elements • Disadvantage: ‐ Computationally more expensive