Issue link: https://resources.randsim.com/i/1504494
21 ©2023 ANSYS, Inc. / Confidential Empirical battery swell model and Electric Current flux report • An empirical-based battery swelling model is now available for the NTGK and the ECM model − Swelling model can be used in both Circuit Network and MSMD methods − By default, swelling strain is computed as ϵ swell = ω (soc-soc ref )/(1+ ω*soc ref ) • New Electric Current Rate is available in the flux report panel when the potential solver is used