Whitepapers

Ansys Electronics 5G Solutions White Paper

Issue link: https://resources.randsim.com/i/1518190

Contents of this Issue

Navigation

Page 1 of 7

simulation@rand.com | RandSIM.com | 888.483.0674 SIwave offers multiple scanners and simulations to identify signal integrity problems and highlight where PCB designs should be reevaluated. For example: • Impedance and crosstalk scanners. These tools scan all single and differentially routed traces and overlay a color map, providing a visual representation of the impedance or crosstalk at each point. • S-parameters. By looking at insertion loss and return loss, designers can determine whether their PCBs meet specific requirements. • Eye diagram analysis. This generates insights into channel compliance and helps determine the cause of data-related failures, such as lost data packets or bit errors. Mastering 5G Technology with Ansys Solutions Figure 1: PCB Signal Integrity with SIwave 2) Addressing PCB Power Integrity As data rates increase, EMI becomes a bigger concern. Ansys SIwave helps PCB designers evaluate power integrity in a variety of ways. • Resonant modes. This functionality visualizes different frequencies and identifies where high voltages occur. • DCIR simulation. This can create a power map across the PCB, showing where high power could affect thermal or signal integrity. The DCIR tool also includes maps of voltage, current vectors, and via current density. • Z-parameters. These show frequency versus impedance, the resonances and impedance spectrum, and the voltage ripple based on the current. Figure 2: PCB Power Integrity with SIwave

Articles in this issue

Links on this page

view archives of Whitepapers - Ansys Electronics 5G Solutions White Paper