Issue link: https://resources.randsim.com/i/1534815
11 ©2025 ANSYS, Inc. Target Stopping Criteria for Fluids (Explore) • Target stopping criteria for fluids - Solution convergence is achieved when the percentage change in the solution variables is less than the specified tolerance - Default tolerance 1% - Enables user control of stopping criteria • Smaller criteria will result in longer run times Laminar flow between rotating and stationary cylinders, tightening target stopping criteria improves accuracy for slowly converging solution F.M. White. Fluid Mechanics. 3rd Edition. McGraw-Hill Book Co., New York, NY., 1994